Sentinam imperium (output fluxus) - commensurationem

Si fluxus testium eventus multum differunt a specificationibus technicis, sentinam output fluunt accommodant.

Photo 1

Ante conspectum principalis sentinam

(I) Audi sentinam moderator

(2) cincinno nut

(III) Adjusting stupra

(IV) Adjusting stupra

(5) Lock nut

(6) Front sentinam moderator

photo 2

(A) visum

(7) Obfirmo nut

(VIII) Adjusting stupra

(9) Obfirmo nut

(X) Adjusting stupra

Temperatio output fluxus sub potestate stabilis potestate

Nota: Summa sentinae fluxus componitur componens sentinam posterioris regulatoris (1) et ante sentinam moderatricem (6) sub potestate stabilis.


Praestare sequentibus gradibus ad primum tempus temperatio perficiendum.

A. Solve seram nucem (7).

B. Turn cochleae componit (8) ad rectam technicam speciem.

Nota: Proventus auge rate convertendo cochleae aptando (8) horologico. Reducere rate fluxum convertendo cochleae aptando (8) counterclockwise. Ad pressionem systematis 20,600 kPa (3,000 psi), cochleae adaptantis (8) ratem fluxum mutat circa 25 L/min (6.6 US GPM) quacumque quarta parte. Mutatio rate fluxus circiter 12 L/min erat (3.2 US GPM) ad pressionem systematis 31.400 kPa (4,550 psi).

C. Obstringere nucem cincinnis (7) usque ad Aureus 155 ± 20 N·m (115 ± 15 lb ft).

2. Facere his gradibus ad perficiendam periodum 2 temperatio: I.

A. Solve seram nucem (9).

B. Turn cochleae accommodans (10) ad rectam technicorum speciem.

Nota: fluxus rate augetur per conversionem cochleae aptando (10) horologico. Reducere rate fluxum convertendo cochleae aptando (10) counterclockwise. Ad 31400 kPa (4550 psi) pressio systematis, cochleae adaptans (10), rate fluxum mutat circa 28 L/min (7.4 US GPM) quacumque quarta parte.

C. Obstringere nucem cincinnis (9) donec torques 120 ± 20 N·m (90 ± 15 lb ft).

Nota: Quaelibet mutatio in fluxu per plenam vicem cochleae adaptantis adhibeatur ut relatio tantum. Vide ut profluvio uti ad sentinam fluere accommodes.


Adjust maximus output fluxus sentinam

1. Accommodare maximum output fluxum anterioris sentinae, lock nucem solve (5).

2. Reducere maximum output fluxum sentinam convertendo cochleae aptando (4) horologico. Maximum output fluxum sentinam auget convertendo cochleae aptando (4) counterclockwise. Cochleae adaequans (4) Mutare ratem fluens circa 8 L/min quaquaversum tractus (2.1 USgpm).

3. Obstringe cincinnam nucis (5) donec torques 235 ± 20 N·m (175 ± 15 lb ft).

4. Accommodare maximum output fluxum sentinae, lock nucem solve (2).

5. Reducere maximum output fluxum sentinae convertendo cochlea (3) clockwise. Auge maximum output fluxum sentinam convertendo cochleae aptando (3) counterclockwise. Adjusting cochleae (3) fluxum rate fluere circa 8 L/min per singulas partes quadrantem (2.1 USgpm).

6. Obstringere nucem cincinnis (2) ad torques 235 ± 20 N·m (175 ± 15 lb ft).

Nota: Quaelibet mutatio in fluxu per plenam vicem cochleae adaptantis adhibeatur ut relatio tantum. Vide ut profluvio uti ad sentinam fluere accommodes.